Countermeasures and reasons of catheter slippage after laparoscopic radical prostatectomy
Xie Jiaokui1 Song Yin'e2 Song Yong3 Fu Weijun3 Wang Chunyang3 Li Hongzhao3 Zhang Xu3
1Department of Urology, Ankang Central Hospital, Ankang 725000, China; 2Department of Dermatology, Ankang Central Hospital; 3Department of Urology, Chinese PLA General Hospital
Abstract:Objective: To investigate the countermeasures and reasons of catheter slippage after laparoscopic radical prostatectomy (LRP).Methods: The clinical data of 5 cases of catheter slippage after LRP during February 2016 to June 2016 in Chinese PLA General Hospital were retrospectively analyzed. The postoperative recovery of the patients after catheter replacement was observed.Results: One case was successfully treated by replacing urinary catheter. One case was treated by ureteroscope successfully. The catheter was replaced in 3 cases under electron flexible cystoscope. Conclusions: The variety of measures can reduce the risk of catheter slippage, including the detailed examination of urinary catheter before operation, subtle manipulation, and the urinary catheter nursing carefully after operation. The replacement of the catheter under electron flexible cystoscope is safe, effective, and worthy of clinical promotion.
谢蛟魁 宋印娥 宋勇 符伟军 王春杨 李宏召 张旭. 浅析腹腔镜前列腺根治性切除术后尿管滑脱原因及处置策略[J]. 微创泌尿外科杂志, 2016, 5(5): 278-280.